standard
National food safety standard Determination of magnesium in foods
17 Dec 2019  点击:275
  • National food safety standard Determination of magnesium in foods
  • GB 5009.241-2017 食品安全国家标准 食品中镁的测定
  • Issuance Date:1491408000
  • Implementation Date :1507305599
  • Translated by:FOODMATE
  • Language:English
  • Format:PDF/DOC/DOCX
  • Pages:7
  • Price:$116
  •  Foreword

    This standard replaces the methods for determination of magnesium specified in GB/T 5009.90-2003 “Determination of iron, magnesium and manganese in foods”, GB/T 9695.21-2008 “Meat and meat products-Method for determination of magnesium content”, GB 5413.21-2010 “National food safety standard-Determination of calcium, iron, zinc, sodium, potassium, magnesium, copper and manganese in foods for infants and young children, milk and milk products”, GB/T 23375-2009 “Determination of copper, iron, zinc, calcium, magnesium and phosphorus content in vegetables and derived products”, GB/T 14609-2008 “Inspection of grain and oils-Determination of copper, iron, manganese, zinc, calcium, magnesium in cereals and derived products by atomic absorption and flame spectrophotometry”, GB/T 18932.12-2002 “Method for the determination of potassium, sodium, calcium, magnesium, zinc, iron, copper, manganese, chromium, lead, cadmium contents in honey-Atomic absorption spectrometry” and NY 82.19-1988 “Method for determination of fruit juice-Determination of calcium and magnesium”.

    Compared with GB/T 5009.90-2003, the major changes of this standard are as follows:

    ——the standard name has been revised to “National food safety standard-Determination of magnesium in foods”;

    ——the sample pretreatment method has been adjusted to wet digestion, microwave digestion, dry ashing and pressure tank digestion;

    ——the flame atomic absorption spectrometry has been retained for the sample determination and the titration method has been deleted;

    ——the inductively coupled plasma emission spectrometry has been added as Method II;

    ——the inductively coupled plasma mass spectrometry has been added as Method III.